Quick answer
A vapour recovery unit (VRU, also spelled vapor recovery unit) is a packaged system that captures hydrocarbon vapours from tanks, loading operations or process vents, turns them back into liquid or usable gas, and returns them to the product stream instead of venting or flaring them. You need one when the vapour losses are large enough to cost money, cause safety or odour problems, or break an emission rule. EPA’s Natural Gas STAR programme reports that VRUs on oil storage tanks can capture about 95 percent of the vapours.
What Is a Vapour Recovery Unit?
A VRU sits between a vapour source and the atmosphere. The source can be a storage tank, a truck or ship loading arm, a separator or a process vent. Instead of letting the vapour escape or burning it, the VRU draws it in, separates the recoverable hydrocarbons and sends them back to a product tank, a gas line or a fuel system.
That is why a VRU does two jobs at once. It cuts emissions, and it keeps product that would otherwise be lost. The balance between those two jobs depends on the site. At a loading terminal the main driver is usually the emission limit. At a production site the main driver is often the value of the recovered gas and liquids.
Where Do the Vapours Come From?
EPA describes three main loss mechanisms in oil storage tanks, and the same ideas apply to most fuel and chemical tanks:
- Flash losses: light components boil off when liquid moves from a higher pressure to a tank at atmospheric pressure.
- Working losses: vapour is pushed out when a tank is filled, or when the liquid level changes or is agitated.
- Standing losses: vapour leaves with daily and seasonal changes in temperature and barometric pressure.
Knowing which loss dominates tells you how steady or how peaky the vapour flow will be. That decides how a VRU should be sized.
How Does a VRU Work in Short?
- Vapour is drawn from the tank or loading point so that it does not vent.
- A separator removes liquid droplets and solids.
- A compressor, ejector or other driver moves the vapour and raises its pressure.
- Cooling, absorption or adsorption turns the recoverable part back into liquid or concentrates it.
- The recovered product goes back to storage, a gas line or onsite fuel. Any leftover gas is treated or sent to a safe outlet.
For the full step-by-step view, including control logic and what happens at start-up, read how a vapor recovery unit works.
Which Type of VRU Do You Need?
The right type depends on the vapour, the flow pattern and where the recovered product goes. This table is a starting point, not a final selection.
| Type | How it works | Typical use | Watch out for |
|---|---|---|---|
| Compressor-based | A rotary screw or vane compressor draws vapour out of low-pressure tanks (EPA). | Production tanks, fuel and chemical tanks | Needs power or an engine driver, and a plan for varying flow |
| Ejector (venturi jet) | A jet ejector replaces the compressor (EPA). | Sites with a suitable motive stream | Needs enough motive pressure, and the right fluid, to work |
| Compression and condensation | Vapour is compressed and cooled until the heavier part condenses. | Mixed hydrocarbon vapours at depots and terminals | Light components stay in the gas and need a second step |
| Adsorption | Activated carbon or a similar bed holds the vapour, then it is regenerated and recovered. | Loading terminals with strict outlet limits | Bed regeneration and heat management |
| Absorption | A liquid absorbent takes up the vapour. | Larger or continuous flows | Absorbent handling and downstream separation |
| Membrane | A selective membrane splits the hydrocarbons from the air or gas. | Vapour streams that suit selective separation | Usually part of a combined system, not stand-alone |
Many terminal systems combine two steps, for example adsorption with absorption. If you are comparing a VRU with a vapour recovery tower, read vapor recovery tower vs VRU.
Where Are VRUs Installed?
- Storage tank farms and depots: see tank storage vapor recovery.
- Truck loading, drum filling and rail: see vapour recovery for truck loading and drum filling.
- Ships, tankers and marine terminals: see marine vapour recovery systems.
- Oil production sites: stock tanks and low-pressure vents, where the recovered gas is sold, reused as fuel or sent to processing.
- Refineries and chemical plants: tanks, process vents and loading points that handle volatile liquids.
How Do You Know If You Need a VRU?
- Tank vents or loading points release vapour you can smell, measure or see on a gas camera.
- The lost product has real value, or you are flaring gas you could sell or burn onsite.
- A permit, an emission limit or a customer audit asks for vapour control.
- Operators or neighbours have raised odour or health concerns.
- You are adding tanks or loading capacity, and the vent load will rise.
If you tick one or more of these, the next step is to measure the vapour, not to pick equipment.
What Should You Check Before Choosing a VRU?
| Question | Why it matters |
|---|---|
| What is in the vapour, and how much is hydrocarbon? | Composition decides the type and the materials. |
| What are the average and peak flows? | A VRU sized only for the average cannot follow peaks, and one sized for the peak runs idle most of the time. |
| What are the vapour pressure, temperature and water content? | These set compressor choice, cooling duty and the risk of condensate or hydrates. |
| Where does the recovered product go? | Back to a tank, into a gas line or to fuel. The destination sets the quality you must reach. |
| What is the hazardous-area class and what utilities are available? | This sets the electrical design, the driver and the installation cost. |
| Which rule or permit applies? | The outlet limit decides how clean the exhaust must be. |
For what is inside the package, read VRU package components and compressor skid.
Which EU Rules Apply?
For petrol storage and loading at terminals, Directive 94/63/EC sets the benchmark. Its Annex II says the mean vapour concentration in the exhaust of a vapour recovery unit, corrected for dilution, must not exceed 35 g per normal cubic metre for any one hour. The same annex lets terminals with a throughput below 25,000 tonnes a year use intermediate vapour storage instead of immediate recovery, and lets terminals that load petrol onto vessels use a vapour incineration unit where recovery is unsafe or technically impossible.
Other products and other site types follow national rules and your own permit. Check the permit conditions before you set a design target. For a wider view, see VRU emissions compliance and VOC limits.
Vapour Recovery Unit FAQ
What does VRU stand for?
Answer: VRU stands for vapour recovery unit. In US spelling it is a vapor recovery unit. Both names describe the same equipment.
How much vapour can a VRU recover?
Answer: EPA’s Natural Gas STAR programme reports that VRUs on oil storage tanks can capture about 95 percent of the vapours. The real figure for your site depends on the vapour, the design and how much time the unit is available.
What is the difference between a VRU and a flare?
Answer: A flare burns the vapour and the product is lost. A VRU recovers the vapour so the product can be sold or reused. Many sites keep a flare or another safe outlet as a back-up for upsets.
What is the difference between a VRU and a vapour recovery tower?
Answer: A vapour recovery tower is a vessel placed ahead of the tanks that lets much of the flash gas separate out. A VRU then handles the vapour that still comes off the tanks. The two are often used together, and the comparison page explains when each one makes sense.
Do I need a VRU on a small tank site?
Answer: It depends on the vapour volume, the value of the product, and any rule or permit that applies. Measure the vapour first. A small, steady vent may need a simpler solution than a full package.
Does one VRU suit every type of vapour?
Answer: No. Light hydrocarbons, heavier fuel vapours and solvent vapours behave differently, so the type and the materials must match the vapour. A vapour analysis is the first step.
How much does a VRU cost?
Answer: The price depends on capacity, vapour type, hazardous-area rating, utilities and the recovery target. A reliable figure needs a vapour data sheet, which is why the first step is a short site review.
Key Facts
- A VRU captures vapour from tanks, loading points or vents and returns the recoverable part to the product stream.
- EPA reports about 95 percent capture on oil storage tanks.
- For petrol terminals, EU Directive 94/63/EC sets a 35 g/Nm3 hourly mean limit on VRU exhaust.
- Measure the vapour flow, peaks and composition before you choose a type.
Sources
- US EPA, Natural Gas STAR: Installing Vapor Recovery Units on Crude Oil Storage Tanks (archived copy).
- US EPA, Natural Gas STAR: Vapor Recovery and Gathering Pipeline Pigging, types of vapor recovery units.
- European Union: Directive 94/63/EC on VOC emissions from the storage of petrol and its distribution from terminals to service stations.
Need Help Choosing a VRU?
Send Rodanco your tank list, product and vapour data, and the rule or permit you need to meet. The team can review it and advise on the right route. See vapor recovery unit consulting or email info@rodanco.nl.